%202005.jpg)
Siltsack® - BMP
Use Siltsack® when you need to keep your catch basins free of silt and
sediment.
| Siltsack®
Style |
Test
Method |
Test
Result |
| Regular Flow |
ASTM D-4884 |
165.0 lbs./in |
| Hi-Flow |
ASTM D-4884 |
114.6 lbs./in |
| Properties |
Test
Method |
Units |
Regular
Flow |
Hi-Flow |
| Grab Tensile |
ASTM D-4632 |
lbs. |
315x300 |
255x275 |
| Grab Elongation |
ASTM D-4632 |
% |
15x15 |
20x15 |
| Puncture |
ASTM D-4833 |
lbs. |
125 |
135 |
| Mullen Burst |
ASTM D-3786 |
Psi |
650 |
420 |
| Trapezoid Tear |
ASTM D-4533 |
lbs. |
120x150 |
40x50 |
| UV Resistance |
ASTM D-4355 |
% |
90 |
90 |
| Apparent Opening |
ASTM D-4751 |
US Sieve |
40 |
20 |
| Flow Rate |
ASTM D-4491 |
Gal/Min/Ft² |
40 |
200 |
| Permittivity |
ASTM D-4491 |
sec-1 |
0.55 |
1.5 |
All properties are Minimum Average Roll Values (MARV)
Key Benefits
 | Cost-effective, easy way to stop silt and sediment from entering catch
basins on construction sites. |
 | Fast and easy to install and maintain. |
 | Available in a high-flow and regular-flow model, Siltsack® also has the
option to add an absorbent pillow for oil containment. |
 | Available in 2' X 2', 2' X 3', 3' X 3', 2' X 4', and custom sizes. |
|
Contact
ETG for pricing information
on item above. |
|